Name | Schroeder Vulsellum Forceps |
Lead Time | 0-3 days |
Competitor | ;EO150R;GL1000;VM573401;VM57-3401;505240;505-240;305595;30-5595;524625;52-4625;MDS7051424;5246-25;EO151R;GL1020;505241;505-241;524635;52-4635;5246-35;5246-25_5246-35; |
Specialty | Obstetrics & Gynecology-Forceps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | seemab surgical |
Sterility | Non-Sterile |
Usage | Reusable |
Schroeder Vulsellum Forceps
2×2 prongs, 10.0 mm wide, 10″ (25.0 cm)?Schroeder Vulsellum Forceps feature 2X2 inward pointed prongs to grip the uterus during surgical procedures. The forceps also feature ring handles for a comfortable and secure grip. They are available straight or curved on flat to accommodate a range of cases.
Description
Shipping & Delivery
Related products
Heaney-Ballentine Hysterectomy Forceps
jaws w/ longitudinal serrations?Heaney-Ballentine Hysterectomy Forceps are used in hysterectomy procedures to clamp off the tough ligament on both sides of the uterus. The forceps feature unique longitudinal serrations to grasp the ligament. Available straight or curved with single or double groove in various lengths to accommodate a wide range of cases.
Delee Ovum Forceps
9-1/2" (24.0 cm)?Delee Ovum Forceps are commonly used for removal of placental tissue or other products of conception from the uterus to prevent infection. The hollow jaws allow the obstetrician to firmly grasp the tissue to be removed. The ring handles feature a lock to hold the jaws in various positions.
Boston Ovum Forceps
Demartel Scalp/Flap Grasping Forceps
5-1/2" (14.0 cm)?Demartel Scalp/Flap Grasping Forceps are commonly used to aid in the delivery of a newborn by grasping scalp of the child with the smooth, flattened blades of the forceps. The blades feature diagonal grooves and two teeth to firmly grasp the scalp. The ring handles allow the obstetrician to comfortably and easily perform the procedure.
Bill Traction Handle
for use w/ all standard handle type o.b. forceps?Bill Traction Handle is designed to increase the accuracy of traction to the path of least resistance. The handle features a claw that is applied to the finger guards of standard obstetrical forceps. The claw is then attached via a vertical rod and movable joint to a handle grip that is held by the obstetrician.
Colins Uterine Elevating Forceps
Billroth Vulsellum & Tumor Seizing Forceps
4x4 sharp prongs, straight, 10-3/4" (27.0 cm) Billroth Vulsellum & Tumor Seizing Forceps feature 4X4 inward pointing prongs that grasp the uterus or tumor masses during surgical procedures. The ring handles allow for a comfortable and secure grip during procedures. Made of premium grade German stainless steel.