Bierer Tenaculum

angled jaws, 5x6 teeth, 9" (22.9 cm) ?Bierer Tenaculum is commonly used in gynecology to stabilize a woman's cervix or uterus during a procedure. The tenaculum features angled jaws and inward facing hooks with 5X6 teeth to firmly grasp the tissue. The ring handles have a lock mechanism to hold the blades in various positions.

Bill Traction Handle

for use w/ all standard handle type o.b. forceps?Bill Traction Handle is designed to increase the accuracy of traction to the path of least resistance. The handle features a claw that is applied to the finger guards of standard obstetrical forceps. The claw is then attached via a vertical rod and movable joint to a handle grip that is held by the obstetrician.

Billroth Vulsellum & Tumor Seizing Forceps

4x4 sharp prongs, straight, 10-3/4" (27.0 cm) Billroth Vulsellum & Tumor Seizing Forceps feature 4X4 inward pointing prongs that grasp the uterus or tumor masses during surgical procedures. The ring handles allow for a comfortable and secure grip during procedures. Made of premium grade German stainless steel.

Blumenthal Ovum Forceps

slightly curved, concave tip, 20.0 mm jaw, coarse teeth, 13" (33.0 cm) Blumenthal Ovum Forceps are ideal in the removal of placental tissue or other products of conception from the uterus to prevent infections. The hollow blades are slightly curved with coarse teeth on the jaws to firmly grasp the tissue to be removed. The concave tip is designed to prevent grasping the fundus of the uterus.

Boston Ovum Forceps

27.0 mm, 13-1/2" (34.3 cm)? Boston Fulcram is commonly used remove tissue, such as the placenta, from the uterus. The fulcram features serrated hollow blades to firmly grasp tissue. The instrument is available in high or low hinge placement, determining how wide the instrument can be opened up

Braun Tenaculum Forceps

straight, 10" (25.0 cm)?Braun Tenaculum Forceps feature ring handles and sharp pointed hooks to seize blood vessels or steady the cervix and uterus in surgery. The ring handles allow for comfortable and controlled use of the forceps.

Clamp

infundibular pelvic clamp, s-curved ?Infundibular Pelvic Clamp is designed to reach high-up structures in the pelvis during vaginal hysterectomy salpingo-oopherectomy procedures. The s-shaped shanks provide optimal contouring ability and are the ideal shape for deep pelvic procedures.

Clark Forceps

longitudinal serrated jaws, side curved?Clark Forceps feature ring handles and longitudinal serrated jaws that are curved to the side. Ideal for channeling around ureters - the longitudinal jaws gently grasp tissue. The forceps are available in various lengths to accommodate a wide range of cases.

Colins Uterine Elevating Forceps

swivel jaws, 10" (25.4 cm)?Collins Uterine Elevating Forceps feature unique swivel jaws to firmly grasp tissue, tumors, or polyps from the uterus by elevating the vaginal wall. The forceps are operated using ring handles for comfortable and controlled use of the instrument.

Corey (Collin) Ovum Forceps

9-1/2" (24.0 cm)Corey (Collin) Ovum Forceps are commonly used in procedures involving the removal of placental or fetal tissue from the uterus. The forceps feature hollow oval jaws to grasp a large amount of tissue to be removed. Made of premium grade German stainless steel for durability and easy sterilization.

Corson Myoma Grasping Forceps

cup jaws, 13" (33.0 cm)?Corson Myoma Grasping Forceps are ideal for the removal of polyps from the uterus. The strong cup jaws ensure proper removal of the polyp with minimal injury to adjacent tissue. The forceps are available in various jaw sizes to accommodate a wide range of cases.

Dartigues Uterine Elevating Forceps

smooth jaws, straight, 10-1/4" (26.0 cm)?Dartigues Uterine Elevating Forceps are designed to remove tissue, tumors, or polyps from the uterus by elevating the vaginal wall. The clamps at the ends of the ring handles curve inward toward the handles. The clamps feature smooth jaws to firmly grasp the tissue to be removed.