Name | Andrews-Pynchon Suction Tube |
Lead Time | 0-3 days |
Competitor | ;BE471;706560;70-6560;170115;170-115;962562501;96-256-25-01;N7557;2109;098508;09-8508;162310;2413768;16-2310;VM21-6318;VM216318;0985-08;BE470;MD613;140054;14-0054;2110;2-110;CH820030;CH8200-30;CH820042;CH8200-42;098509;09-8509;526525;536220;2414133;0985-09;0985-08_0985-09; |
Specialty | General Instruments-Suction Tubes, Needles & Probes – Suction Tubes |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | seemab surgical |
Sterility | Non-Sterile |
Usage | Reusable |
Suction Tube
Suction Tube
9″ (22.9 cm) overall length
Andrews-Pynchon Suction Tube is designed with a tapered handle to create a comfortable and secure grip when held. The suction tube itself is slightly curved and contains either a removable tip or a removable shaft to assist with different suction processes throughout a surgical procedure. This 9″ long instrument is ideal for removing fluid or blood that may interfere with the operating area.
SKU:
VI-01-874
Category: Suction Tubes, Needles & Probes
Description
Shipping & Delivery
Related products
Grooved Director & Tongue Tie – Probe Point
Grooved Director & Tongue Tie - Probe Point
stainless steel, probe point
Grooved Director and Tongue Tie is a stainless steel instrument that contains a probe point on one end typically used to examine the mouth in young children. The other end consists of a flat butterfly-shaped end. In frenotomy procedures that require stabilizing the tongue, the grooved director can assist in this process and provide a better view for the surgeon. Different sizes are available to accommodate different cases.
Yankauer Suction Tube – Pediatric
Suction Tube
small pattern, narrow handle (pediatric), w/ removable tip, 8-1/4" (21.0 cm) overall length
Yankauer Suction Tube is designed to be used during general procedures involving pediatrics due to the narrow handle and smaller pattern. The reason of using this tube is to clean the surgical site, thereby also removing debris or fluids and reducing the chance for infection. The end of the tube contains a removable bulb-shaped tip, and the overall length is 8 ?."
Tongue Tie – Plain Point
Tongue Tie - Plain Point
stainless steel, plain point
Grooved Director and Tongue Tie contains a plain point at one end and a butterfly-shaped director on the other end. This stainless steel instrument is typically used during a frenotomy to lift the tongue back and expose the frenulum. The frenulum would rest on the grooved part of the director and then be cut with iris scissors. Depending on the patient, this device is offered in various lengths.
Gallbladder Trocar
Gallbladder Trocar
6" (15.2 cm)
Ochsner Gallbladder Trocar is a 6" long instrument and is available in various French circumferences. With the help of a sharp point, the main purpose of this trocar is to drain a fluid-filled cavity. For example, if any pus or mucus resides in the gallbladder, this instrument is able to withdraw that liquid.
Vein Stripper
Vein Stripper
complete set in stainless steel sterilizing case, includes: traction cable, handle, plastic probe tip, metal probe tip, olive adaptors (6.0 mm, 9.0 mm & 12.0 mm)
Nabatoff Vein Stripper is a complete set loaded in a stainless steel sterilizing case that includes several tools such as traction cable, handle, probe tips, and olive adaptors. This instrument is typically used during procedures that involve the removal of varicose veins. Once an incision is made around the area, the wire is inserted into the vein and tied so that the vein can be pulled out.
Suction Tube
Suction Tube
w/ removable tip
Yankauer Suction Tube comes with a tip that can be removeved to allow access to tighter spaces. If these tips get lost, however, they can be purchased separately to be used only for the Yankauer suction tube. This device is also long in length and can range from 10 ?" to 18" depending on the operation. The handle of this device contains an end that can be connected to a suction source in order to provide the suction power needed to remove fluids or debris away from the surgical site.
Frazier Suction Tube
Frazier Suction Tube
angled, w/ finger cut-off, 4" (10.2 cm) working length
Frazier Suction Tube has an angled tube and is available in a variety of different sizes and widths depending on the operation. This tube has a finger cut-off on a 4" working length and performs similar to a pump with a suction force. The purpose of this suction force is to be used in general operations in which materials or fluid, typically blood, need to be removed to provide a cleaner working area.
Adson Suction Tube
Adson Suction Tube
w/ finger cut-off, curved
Adson Suction Tube contains a finger cut-off valve to place rest the finger on and a grip handle for a better hold. This instrument is available in several different French measurements on a 5" or 8" working length. The intended purpose of this suction tube with a slightly curved tip is to remove any excess liquids or fluids that are present on the surgical site. In this way, the surgeon may have a clear view of the area being operated.